Home/Brands/ Teledyne FLIR/Fixed Thermal Cameras

FLIR Axxx-Series Smart Sensor Fixed-Mount Thermal Camera

Brand : Teledyne FLIR
Categories : Fixed Thermal Cameras , Lense

The FLIR Axxx-Series Thermal Smart Sensor Camera has the features automation solution providers need for complex monitoring applications, including critical infrastructure, product quality, and early fire detection. The Smart Sensor configuration includes multiple measurement tools and alarms while also providing computing-on-the-edge, with analytics performed at the camera level for immediate results. With a range of lens choices, motorized focus control, and unrivaled connectivity, A400/A500/A700 cameras offer unmatched power and flexibility. Easy configuration allows you to tailor this monitoring system to your company’s quality, productivity, maintenance, and safety needs.

GET QUOTE

WORLD-CLASS THERMAL IMAGING

Provides exceptional image quality with up to 640 × 480 (307,200 pixels) and superior measurement accuracy (<±2°C)

ADVANCED ANALYTICS FOR IMPROVED DECISIONS SUPPORT

Edge analytics with features such as a polygon function (advanced) help you make immediate, informed decisions

FLEXIBLE MEASUREMENT FEATURES FOR A WIDE RANGE OF APPLICATIONS

Includes options to adjust measurements and alarms based on a reference temperature source (advanced)


Specifications

  • EMC

    • ETSI EN 301 489-1 (radio) • ETSI EN 301 489-17 (radio) • EN 61000-4-8 (magnetic field) • FCC 47 CFR Part 15 Class B (emission US) • ISO 13766-1 (EMC - Earth-moving and building construction machinery) • EN ISO 14982 (EMC - Agricultural and forestry machinery)

  • WiFi

    Optional feature purchased separately. RP-SMA, female connector

  • Accuracy

    ±2°C (±3.6°F) or ±2% of reading, for ambient temperature 15°C–35°C (59°F–95°F) and object temperature above 0°C (32°F)

  • Encoding

    Video stream: H.264, MPEG4, or MJPEG Radiometric stream: Compressed JPEG-LS, FLIR radiometric

  • Alarm Output

    • Digital out • E-mail (SMTP) (push) • EtherNet/IP (pull) • File transfer (FTP) (push) • Modbus TCP master write (push) • Modbus TCP slave (pull) • MQTT (push) • Query over RESTful API (pull) • ONVIF • Store image or video

  • Digital Inputs

    2x opto-isolated, Vin(low)= 0–1.5 V, Vin(high)= 3–25 V

  • Alarm Functions

    On any selected measurement function, digital in, and internal camera temperature

  • Digital Outputs

    3x opto-isolated, 0–48 V DC, max. 350 mA; solid-state opto relay; 1x dedicated as Fault output (NC)

  • Image Frequency

    30 Hz

  • Ethernet Interface

    Wired, Wi-Fi (optional)

  • Digital Output Purpose

    • As a function of alarm, output to external device • Fault (NC)

  • Thermal Sensitivity/NETD

    Lens dependent

  • Digital I/O connector type

    M12 12-pin A-coded, Male (shared with external power)

  • WiFi

    Optional feature purchased separately. RP-SMA, female connector

  • RS-232

    NA

  • Encoding

    Video stream: H.264, MPEG4, or MJPEG Radiometric stream: Compressed JPEG-LS, FLIR radiometric

  • Ethernet

    For control, result, image, and power

  • Multicast

    Yes

  • Ethernet Type

    1000 Mbps

  • Image Storage

    Records up to 100 FLIR radiometric JPEG; storage as function of: alarm, scheduling, or user interaction (camera web)

  • Video Storage

    Records up to 10 H.264 videos; storage as function of alarm — 5 sec. before alarm and 5 sec. after alarm.

  • Digital Inputs

    2x opto-isolated, Vin(low)= 0–1.5 V, Vin(high)= 3–25 V

  • Ethernet Power

    Power over Ethernet, PoE IEEE 802.3af class 3

  • Digital Outputs

    3x opto-isolated, 0–48 V DC, max. 350 mA; solid-state opto relay; 1x dedicated as Fault output (NC)

  • Ethernet Standard

    IEEE 802.3

  • Ethernet Interface

    Wired, Wi-Fi (optional)

  • Ethernet Protocols

    • EtherNet/IP • IEEE 1588 • Modbus TCP Master • Modbus TCP Slave • MQTT • SNMP • TCP, UDP, SNTP, RTSP, RTP, HTTP, HTTPS, ICMP, IGMP, sftp (server), FTP (client), SMTP, DHCP, MDNS (Bonjour), uPnP

  • Digital input purpose

    NUC, NUC disable, alarm

  • Digital Output Purpose

    • As a function of alarm, output to external device • Fault (NC)

  • Ethernet Communication

    TCP/IP socket-based FLIR proprietary

  • Ethernet Connector Type

    M12 8-pin X-coded, female; RP-SMA, female

  • Digital I/O connector type

    M12 12-pin A-coded, Male (shared with external power)

  • Digital I/O isolation voltage

    500 VRMS

  • Focus

    One-shot contrast, motorized, and manual

  • Overlay

    With / Without

  • Readout

    Measurement results: • Ethernet/IP (pull) • Modbus TCP master (push) • Modbus TCP slave (pull) • MQTT (push) • Query over REST API (pull) • Measurements and still image (radiometric JPEG, visual 640 × 480, visual 1280 × 960), read access only • Web interface

  • Image Source

    Video stream 0: visual / IR / MSX® (visual camera is an optional feature) Video stream 1: visual Radiometric video stream: IR

  • Pixel Format

    Video stream: YUV411 Radiometric stream: MONO 16

  • IR Resolution

    320 × 240

  • Detector Pitch

    17 µm

  • Spectral Range

    7.5–14 µm

  • Visible Camera

    Optional accessory; disabled when 80° lens in use

  • Image Frequency

    30 Hz

  • Multi-Streaming

    Yes

  • Video Streaming

    RTSP protocol

  • Available Lenses

    6°, 24°, 14°, 42°, 2.0x Micro, Dual FOV (14° + 24°) athermalized lenses, 80°

  • Contrast Enhancement

    FSX® / Histogram equalization (IR only)

  • Streaming Resolution

    Video stream 0: 640 × 480 pixels Video stream 1: 1280 × 960 pixels Radiometric stream: 320 × 240 pixels

  • Focal Plane Array (FPA)

    Uncooled microbolometer

  • Thermal Sensitivity/NETD

    Lens dependent

  • Radiometric IR video streaming

    RTSP protocol

  • Accuracy

    ±2°C (±3.6°F) or ±2% of reading, for ambient temperature 15°C–35°C (59°F–95°F) and object temperature above 0°C (32°F)

  • Alarm Output

    • Digital out • E-mail (SMTP) (push) • EtherNet/IP (pull) • File transfer (FTP) (push) • Modbus TCP master write (push) • Modbus TCP slave (pull) • MQTT (push) • Query over RESTful API (pull) • ONVIF • Store image or video

  • Alarm Functions

    On any selected measurement function, digital in, and internal camera temperature

  • Measurement Tools

    10 spotmeters, 10 boxes or mask polygons, 3 Deltas (difference any value/reference/external lock), 2 isotherms (above/below/interval), 2 iso-coverage, 1 reference temperature, 2 lines, 1 polyline

  • Measurement Presets

    Yes

  • Measurement Corrections

    Global object parameters; local parameters per analyze function

  • Object Temperature Range

    -20°C to 120°C (-4°F to 248°F), 0°C to 650°C (32°F to 1202°F), 300°C to 1500°C (572°F to 3632°F)

  • Automatic hot & cold detection

    Max./min. temperature value and position shown within box

  • Atmospheric transmission correction

    Based on inputs of distance, atmospheric temperature, and relative humidity

  • Weight

    0.82 kg (1.8 lb), camera only

  • Base Mounting

    4× M4 on 4 sides

  • Housing material

    Aluminium

  • Size (L x W x H)

    123 × 77 × 77 mm (4.84 × 3.03 × 3.03 in)

  • EMC

    • ETSI EN 301 489-1 (radio) • ETSI EN 301 489-17 (radio) • EN 61000-4-8 (magnetic field) • FCC 47 CFR Part 15 Class B (emission US) • ISO 13766-1 (EMC - Earth-moving and building construction machinery) • EN ISO 14982 (EMC - Agricultural and forestry machinery)

  • Shock

    IEC 60068-2-27, 25 g

  • Corrosion

    • ISO 12944 C4 G or H • EN60068-2-11

  • Vibration

    • IEC 60068-2-6, 0.15 mm at 10–58 Hz and 2 g at 58–500 Hz, sinusoidal • IEC 61373 Cat 1 (Railway)

  • Encapsulation

    IEC 60529, IP 54, IP66 with accessory

  • Radio Spectrum

    • FCC 47 CFR Part 15 Class C (2.4 GHz band US) • FCC 47 CFR Part 15 Class E (5 GHz band US) • RSS-247 (2.4 GHz and 5 GHz band Canada) • ETSI EN 300 328 V2.1.1 (2.4 GHz band EU) • ETSI EN 301 893 V2.1.1 (5 GHz band EU)

  • Tripod Mounting

    UNC ¼″-20 on 2 sides

  • ONVIF Conformance

    Yes. ONVIF Profile S

  • Operating Temperature Range

    -20°C to 50°C (–4°F to 122°F): • -20°C to 40°C (-4°F to 104°F) (in free air) • 40°C to 50°C (104°F to 122°F) (mounted on cooling plate accessory) Maximum camera case temperature: 65°C (149°F)

  • Humidity (Operating and Storage)

    IEC 60068-2-30/24 hours, 95% relative humidity, 25°C–40°C (77°F–104°F)/2 cycles

  • External Voltage

    Allowed range 18–56 V DC

  • Power Connection

    M12 12-pin A-coded, male (shared with Digital I/O)

  • Power Consumption

    • 7.5 W at 24 V DC typical • 7.8 W at 48 V DC typical • 8.1 W at 48 V PoE typical

  • External Power Operation

    24/48 V DC 8 W max

For Sales & Support