FLIR A50/A70 Image Streaming Fixed-Mount Thermal Camera
Brand :
Teledyne FLIR
Categories :
Fixed Thermal Cameras
, Lense
FLIR A50 and A70 Thermal Image Streaming Cameras are the right choice for users who want camera control capabilities and image streaming over Ethernet, as well as flexibility to perform analytics and raw data collection on thermal characteristics using preferred software applications. With options for Wi-Fi, an integrated visual camera, compressed radiometric image streaming, and ONVIF S compatibility (advanced version only), these small and lightweight fixed-focus automation cameras will optimize process control and quality assurance to improve yield, product quality, through-put time, and lower costs.
Trouble-Free Integration
GigE Vision and GenICam compliant for camera control and thermal/visual image video streaming over Ethernet into third-party machine vision applications.
Rugged and Easy to Install
Install the lightweight, IP66 rated camera with M8/12 connectors in any location – with multiple mounting options.
Improve Production and Quality
Quickly access thermal characteristics, with up to 640 × 480 (307,200 pixels) resolution and ±2°C accuracy, allowing users to optimize production settings and product quality.
Specifications
-
EMC
• ETSI EN 301 489-1 (radio) • ETSI EN 301 489-17 (radio) • EN 61000-4-8 (magnetic field) • FCC 47 CFR Part 15 Class B (emission US) • ISO 13766-1 (EMC - Earth-moving and building construction machinery) • EN ISO 14982 (EMC - Agricultural and forestry machinery)
-
WiFi
Optional feature purchased separately. RP-SMA, female connector
-
Accuracy
±2°C (±3.6°F) or ±2% of reading, for ambient temperature 15°C–35°C (59°F–95°F) and object temperature above 0°C (32°F)
-
Encoding
RTSP video streaming: H.264 / MPEG4 / MJPEG RTSP radiometric streaming: compressed JPEG-LS, FLIR radiometric GVSP video streaming: uncompressed GVSP radiometric streaming: temperature linear and FLIR radiometric
-
f-number
1.4
-
Alarm Output
NA
-
Digital Inputs
2x opto-isolated, Vin(low)= 0–1.5 V, Vin(high)= 3–25 V
-
Image Fequency
30 Hz
-
Alarm Functions
NA
-
Digital Outputs
3x opto-isolated, 0–48 V DC, max. 350 mA; solid-state opto relay; 1x dedicated as Fault output (NC)
-
Ethernet Interface
Wired, Wi-Fi (optional)
-
Digital Output Purpose
Programmatically set; fault (NC)
-
Thermal Sensitivity/NETD
<35 mK
-
Digital I/O connector type
M12 12-pin A-coded, Male (shared with external power)
-
WiFi
Optional feature purchased separately. RP-SMA, female connector
-
RS-232
M8 A-coded, male connector
-
Encoding
RTSP video streaming: H.264 / MPEG4 / MJPEG RTSP radiometric streaming: compressed JPEG-LS, FLIR radiometric GVSP video streaming: uncompressed GVSP radiometric streaming: temperature linear and FLIR radiometric
-
Ethernet
For control, result, image, and power
-
Multicast
Yes
-
Ethernet Type
1000 Mbps
-
Image Storage
NA
-
Digital Inputs
2x opto-isolated, Vin(low)= 0–1.5 V, Vin(high)= 3–25 V
-
Ethernet Power
Power over Ethernet, PoE IEEE 802.3af class 3
-
Digital Outputs
3x opto-isolated, 0–48 V DC, max. 350 mA; solid-state opto relay; 1x dedicated as Fault output (NC)
-
Ethernet Standard
IEEE 802.3
-
Ethernet Interface
Wired, Wi-Fi (optional)
-
Ethernet Protocols
• IEEE 1588 • SNMP • TCP, UDP, SNTP, RTSP, RTP, HTTP, HTTPS, ICMP, IGMP, sftp (server), FTP (client), SMTP, DHCP, MDNS (Bonjour), uPnP, GVSP, GVCP
-
Serial Communication
Pan & Tilt control. Pelco D standard HW interface: RS232 and RS485 exclusively
-
Digital input purpose
NUC; NUC disable; image TAG (Start, Stop, General); image flow control (acc. SFNC 2.3): • Single frame (on trigg) • Multiframe (on trigg) • Continuous
-
Digital Output Purpose
Programmatically set; fault (NC)
-
Ethernet Communication
• GigE Vision ver. 1.2 • Client API GenICam compliant • TCP/IP socket-based FLIR proprietary
-
Ethernet Connector Type
M12 8-pin X-coded, female; RP-SMA, female
-
ONVIF Profile S Compliant
Yes
-
Digital I/O connector type
M12 12-pin A-coded, Male (shared with external power)
-
Digital I/O isolation voltage
500 VRMS
-
MSX
Yes, included in visual camera option
-
Focus
Fixed, adjustable with included tool
-
Overlay
Without
-
Readout
No measurements readouts, only streamed video
-
f-number
1.4
-
Focal Length
14.3 mm (0.56 in)
-
IR Resolution
464 × 348
-
Detector Pitch
17 µm
-
Image Fequency
30 Hz
-
Spectral Range
7.5–14 µm
-
Visible Camera
Optional accessory
-
Video Streaming
RTSP or GVSP (GigE Vision) protocols
-
Field of view (FOV)
29° × 22°
-
Contrast Enhancement
FSX® / Histogram equalization (IR only)
-
Streaming Resolution
RTSP video streaming, source 0: 640 × 480 pixels RTSP video streaming, source 1: 1280 × 960 pixels RTSP radiometric streaming: 464 × 348 pixels GVSP video streaming: 640 × 480 pixels GVSP radiometric streaming: 464 × 348 pixels
-
Minimum Focus Distance
0.25 m (0.82 ft)
-
Focal Plane Array (FPA)
Uncooled microbolometer
-
Thermal Sensitivity/NETD
<35 mK
-
Radiometric IR video streaming
GigE Vision and RTSP
-
Accuracy
±2°C (±3.6°F) or ±2% of reading, for ambient temperature 15°C–35°C (59°F–95°F) and object temperature above 0°C (32°F)
-
Alarm Output
NA
-
Alarm Functions
NA
-
Measurement Tools
NA
-
Measurement Presets
NA
-
Measurement Corrections
NA
-
Object Temperature Range
–20 to 175°C (–4 to 347°F) 175 to 1000°C (347 to 1832°F)
-
Automatic hot & cold detection
NA
-
Atmospheric transmission correction
Based on inputs of distance, atmospheric temperature, and relative humidity
-
Weight
519g (1.14lb) without bottom cooling plate
-
Base Mounting
4 x M2.5 direct into camera or 4x 10-32 UNF onto bottom cooling plate
-
Housing material
Aluminium
-
Size (L x W x H)
107 × 67 × 57 mm (4.21 × 2.64 × 2.24 in)
-
EMC
• ETSI EN 301 489-1 (radio) • ETSI EN 301 489-17 (radio) • EN 61000-4-8 (magnetic field) • FCC 47 CFR Part 15 Class B (emission US) • ISO 13766-1 (EMC - Earth-moving and building construction machinery) • EN ISO 14982 (EMC - Agricultural and forestry machinery)
-
Shock
IEC 60068-2-27, 25 g
-
Corrosion
• ISO 12944 C4 G or H • EN60068-2-11
-
Vibration
• IEC 60068-2-6, 0.15 mm at 10–58 Hz and 2 g at 58–500 Hz, sinusoidal • IEC 61373 Cat 1 (Railway)
-
Encapsulation
IEC 60529 and IP66
-
Radio Spectrum
• FCC 47 CFR Part 15 Class C (2.4 GHz band US) • FCC 47 CFR Part 15 Class E (5 GHz band US) • RSS-247 (2.4 GHz and 5 GHz band Canada) • ETSI EN 300 328 V2.1.1 (2.4 GHz band EU) • ETSI EN 301 893 V2.1.1 (5 GHz band EU)
-
Tripod Mounting
4 x M2.5 direct into camera or 4x 10-32 UNF onto bottom cooling plate
-
Operating Temperature Range
–20 to 50°C (–4 to 122°F) Bottom cooling plate is needed in temperatures above 40°C (104°F). Maximum internal temperature sensor: 70°C (158°F)
-
Humidity (Operating and Storage)
IEC 60068-2-30/24 hours, 95% relative humidity, 25–40°C (77–104°F)/2 cycles EN60068-2-38
-
External Voltage
Allowed range 18–56 V DC
-
Power Connection
M12 12-pin A-coded, male (shared with Digital I/O)
-
Power Consumption
• 7.5 W at 24 V DC typical • 7.8 W at 48 V DC typical • 8.1 W at 48 V PoE typical
-
External Power Operation
24/48 V DC 8 W max
-
Web interface
Yes